ACI楼宇自控设备和配件Building automation equipment and accessories
A C I 楼宇自控产品-温度控制-湿度控制-压力控制-各类传感器-电子模块配件…….
100 Ohm Platinum Resistance Temperature Detectors (PRTD)
A/100-2w-R2
A/100-2w-R2S
A/100-2w-R2O
A/100-2w-R2SO
-RJ4 or RJ6 or RS232
-(DF) or (DC) LCD
A/100-2w-D( )-PB (4″, 8″, 12″, 18″ )
A/100-2w-I( )-NWGD (2.5″, 4″, 6″ )
A/100-2w-I( )-GD (2.5″, 4″, 6″ )
A/100-2w-S-GD
A/100-2w-O
A/100-2w-W
A/100-2w-W-6′
A/100-3W-A12′-PB
A/100-3W-A24′-PB
A/100-2w-RA18″-PB
A/100-2w-RA24″-PB
A/100-2w-RA36″-PB
A/100-2w-SP
A/100-2w-AP
A/100-2w-BP
A/100-2w-BP-20’Z
A/100-2w-DO ( ) (4″, 8″, 12″, 18″ )
A/100-2w-DO ( )6’CL2P (4″, 8″, 12″, 18″ )
A/100-2w-DO ( )10’CL2P (4″, 8″, 12″, 18″ )
A/100-2w-DO ( )20’CL2P (4″, 8″, 12″, 18″ )
A/100-2w-BBS
A/100-2w-SBS
A/100-2w-PBS
1000 Ohm Platinum Resistance Temperature Detectors (PRTD)
A/1K-2w-R2
A/1K-2w-R2S
A/1K-2w-R2O
A/1K-2w-R2SO
-RJ4 or RJ6 or RS232
-(DF) or (DC) LCD
A/1K-2w-D( )-PB (4″, 8″, 12″, 18″ )
A/1K-2w-I( )-NWGD (2.5″, 4″, 6″ )
A/1K-2w-I( )-GD (2.5″, 4″, 6″ )
A/1K-2w-S-GD
A/1K-2w-O
A/1K-2w-W
A/1K-2w-W-6′
A/1K-3W-A12′-PB
A/1K-3W-A24′-PB
A/1K-2w-FA12′-PB
A/1K-2w-FA24′-PB
A/1K-2w-RA18″-PB
A/1K-2w-RA24″-PB
A/1K-2w-RA36″-PB
A/1K-2w-SP
A/1K-2w-AP
A/1K-2w-BP
A/1K-2w-BP-20’Z
A/1K-2w-DO ( ) (4″, 8″, 12″, 18″ )
A/1K-2w-DO ( )6’CL2P (4″, 8″, 12″, 18″ )
A/1K-2w-DO ( )10’CL2P (4″, 8″, 12″, 18″ )
A/1K-2w-DO ( )20’CL2P (4″, 8″, 12″, 18″ )
A/1K-2w-BBS
A/1K-2w-SBS
A/1K-2w-PBS
A/1K-LTS-10′
A/TUC2
A/TUC2-Fan
100 Ohm Cryogenic Platinum Resistance Temperature Detectors (PRTD)
A/100-3w-LT-D( )(4″, 8″, 12″, 18″ )
A/100-3w-LT-I( )( 2.5″, 4″, 6″ )
A/100-3w-LTS-10′
A/100-3w-LT-O
1000 Ohm Cryogenic Platinum Resistance Temperature Detectors (PRTD)
A/1K-3w-LT-D( ) Duct (4″, 8″, 12″, 18″ )
A/1K-3w-LT-I( ) Immersion ( 2.5″, 4″, 6″ )
A/1K-3w-LTS-10′ Remote Probe
A/1K-3w-LT-O Outdoor Air
100 Ohm High Temperature Platinum Resistance Temperature Detectors (PRTD)
A/100-3w-HT-D( ) Duct (4″, 8″, 12″, 18″ )
A/100-3w-HT-I( ) Immersion ( 2.5″, 4″, 6″ )
A/100-3w-HT-10′ Remote Probe
1000 Ohm High Temperature Platinum Resistance Temperature Detectors (PRTD)
A/1K-3w-HT-D( ) Duct (4″, 8″, 12″, 18″ )
A/1K-3w-HT-I( ) Immersion ( 2.5″, 4″, 6″ )
A/1K-3w-HT-10′ Remote Probe
1000 Ohm Nickel RTD
A/1K-NI-R2 Room
A/1K-NI-R2S Room w/ Setpoint
A/1K-NI-R2O Room w/ Override
A/1K-NI-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/1K-NI-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/1K-NI-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/1K-NI-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/1K-NI-S-GD Strap-On, 2-5″ Pipe
A/1K-NI-O Outdoor Air
A/1K-NI-W Raw Sensor in plastic cup
A/1K-NI-A12′-PB Copper Averaging 12′
A/1K-NI-A24′-PB Copper Averaging 24′
A/1K-NI-FA12′-PB Flexible Cable Averaging 12′
A/1K-NI-FA24′-PB Flexible Cable Averaging 24′
A/1K-NI-RA18″-PB S.S. Rigid Averaging 18″
A/1K-NI-RA24″-PB S.S. Rigid Averaging 24″
A/1K-NI-RA36″-PB S.S. Rigid Averaging 36″
A/1K-NI-SP Stainless Steel Plate
A/1K-NI-AP Aluminum Plate
A/1K-NI-BP Bullet Probe
A/1K-NI-BP-20’Z Bullet Probe, 20′ Zip Cord
A/1K-NI-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/1K-NI-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/1K-NI-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/1K-NI-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/1K-NI-BBS Brass Button Sensor
A/1K-NI-SBS Stainless Steel Button Sensor
A/1K-NI-PBS Plastic Button Sensor
A/1K-NI-FRZ2″-30′ Freezer Remote Probe,30′ Leads
A/TUC2 Microprocessor LCD Display Temp
A/TUC2-Fan Microprocessor LCD Display Temp
1000 Ohm (.375 Coefficient) Platinum RTD
A/375-R2 Room
A/375-R2S Room w/ Setpoint
A/375-R2O Room w/ Override
A/375-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/375-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/375-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/375-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/375-S-GD Strap-On, 2-5″ Pipe
A/375-O Outdoor Air
A/375-W Raw Sensor in plastic cup
A/375-A12′-PB Copper Averaging 12′
A/375-A24′-PB Copper Averaging 24′
A/375-RA18″-PB S.S. Rigid Averaging 18″
A/375-RA24″-PB S.S. Rigid Averaging 24″
A/375-RA36″-PB S.S. Rigid Averaging 36″
A/375-SP Stainless Steel Plate
A/375-AP Aluminum Plate
A/375-BP Bullet Probe
A/375-BP-20’Z Bullet Probe, 20′ Zip Cord
A/375-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/375-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/375-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/375-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/375-BBS Brass Button Sensor
A/375-SBS Stainless Steel Button Sensor
A/375-PBS Plastic Button Sensor
A/TUC2 Microprocessor LCD Display Temp
A/TUC2-Fan Microprocessor LCD Display Temp
1000 Ohm Balco RTD
A/Balco-R2 Room
A/Balco-R2S Room w/ Setpoint
A/Balco-R2O Room w/ Override
A/Balco-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/Balco-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/Balco-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/Balco-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/Balco-S-GD Strap-On, 2-5″ Pipe
A/Balco-O Outdoor Air
A/Balco-W Raw Sensor in plastic cup
A/Balco-W-6′ Raw Sensor w/ 6′ Leads
A/Balco-A12′-PB Copper Averaging 12′
A/Balco-A24′-PB Copper Averaging 24′
A/Balco-SP Stainless Steel Plate
A/Balco-AP Aluminum Plate
A/Balco-BP Bullet Probe
A/Balco-BBS Brass Button Sensor
A/Balco-SBS Stainless Steel Button Sensor
A/Balco-PBS Plastic Button Sensor
2000 Ohm Silicon RTD
A/2K-R2 Room
A/2K-R2S Room w/ Setpoint
A/2K-R2O Room w/ Override
A/2K-R2SO Room w/ Setpoint & Override
A/2K-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/2K-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/2K-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/2K-S-GD Strap-On, 2-5″ Pipe
A/2K-O Outdoor Air
A/2K-W Raw Sensor in plastic cup
A/2K-A12′-PB Copper Averaging 12′
A/2K-A24′-PB Copper Averaging 24′
A/2K-SP Stainless Steel Plate
A/2K-BP Bullet Probe
A/2K-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/2K-BBS Brass Button Sensor
A/2K-SBS Stainless Steel Button Sensor
1035 RTD
A/1035-R2 Room
A/1035-R2S Room w/ Setpoint
A/1035-R2O Room w/ Override
A/1035-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/1035-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/1035-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/1035-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/1035-S-GD Strap-On, 2-5″ Pipe
A/1035-O Outdoor Air
A/1035-W Raw Sensor in plastic cup
A/1035-A12′ Copper Averaging 12′
A/1035-A24′ Copper Averaging 24′
A/1035-RA18″-PB S.S. Rigid Averaging 18″
A/1035-RA24″-PB S.S. Rigid Averaging 24″
A/1035-RA36″-PB S.S. Rigid Averaging 36″
A/1035-SP Stainless Steel Plate
A/1035-AP Aluminum Plate
A/1035-BP Bullet Probe
A/1035-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/1035-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/1035-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/1035-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/1035-BBS Brass Button Sensor
A/1035-SBS Stainless Steel Button Sensor
A/1035-PBS Plastic Button Sensor
500 Ohm Balco RTD
A/500B-R2 Room
A/500B-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/500B-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/500B-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/500B-S-GD Strap-On, 2-5″ Pipe
A/500B-O Outdoor Air
A/500B-W Raw Sensor in plastic cup
A/500B-SP Stainless Steel Plate
A/500B-BP Bullet Probe
A/500B-BBS Brass Button Sensor
A/500B-SBS Stainless Steel Button Sensor
AD592 (2 Wire) & AD592-10K (3 Wire) Semiconductor Sensors
A/592-R2 Room
A/592-R2S Room w/ Setpoint
A/592-R2O Room w/ Override
A/592-R2SO Room w/ Setpoint & Override
-(DF) or (DC) LCD LCD option, add to part # above
A/592-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/592-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/592-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/592-S-GD Strap-On, 2-5″ Pipe
A/592-O Outdoor Air
A/592-W Raw Sensor in plastic cup
A/592-A12′-PB Copper Averaging 12′
A/592-A24′-PB Copper Averaging 24′
A/592-SP Stainless Steel Plate
A/592-BP Bullet Probe
A/592-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/592-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/592-BBS Brass Button Sensor
A/592-SBS Stainless Steel Button Sensor
LM34 Semiconductor Sensors
A/34-R2 Room
A/34-R2S Room w/ Setpoint
A/34-R2O Room w/ Override
A/34-R2SO Room w/ Setpoint & Override
-(DF) or (DC) LCD LCD option, add to part # above
A/34-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/34-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/34-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/34-S-GD Strap-On, 2-5″ Pipe
A/34-O Outdoor Air
A/34-W Raw Sensor in plastic cup
A/34-A12′-PB Copper Averaging 12′
A/34-A24′-PB Copper Averaging 24′
A/34-SP Stainless Steel Plate
A/34-BP Bullet Probe
A/34-BBS Brass Button Sensor
A/34-SBS Stainless Steel Button Sensor
100 Ohm Temperature Transmitters
A/TT100( )-R Room
A/TT100( )-RS Room w/ Setpoint
A/TT100( )-RO Room w/ Override
A/TT100( )-RSO Room w/ Setpoint & Override
-(DF) or (DC) LCD LCD option, add to part # above
A/TT100( )-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/TT100( )-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/TT100( )-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/TT100( )-S-GD Strap-On, 2-5″ Pipe
A/TT100( )-O Outdoor Air
A/TT100( )-A12′ Copper Averaging 12′
A/TT100( )-A24′ Copper Averaging 24′
A/TT100( )-RA18″-PB S.S. Rigid Averaging 18″
A/TT100( )-RA24″-PB S.S. Rigid Averaging 24″
A/TT100( )-RA36″-PB S.S. Rigid Averaging 36″
A/TT100( )-SP Stainless Steel Plate
A/TT100( )-BP Bullet Probe
A/TT100( )-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/TT100( )-BO Transmitter Board Only
Optional Potted TT Board (not available in Room and EH enclosures)
1K Ohm Temperature Transmitters (Standard output is 4-20mA, but 2-10VDC and 1-5VDC outputs available)
A/TT1K( )-R Room
A/TT1K( )-RS Room w/ Setpoint
A/TT1K( )-RO Room w/ Override
A/TT1K( )-RSO Room w/ Setpoint & Override
-(DF) or (DC) LCD LCD option, add to part # above
A/TT1K( )-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/TT1K( )-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/TT1K( )-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/TT1K( )-S-GD Strap-On, 2-5″ Pipe
A/TT1K( )-O Outdoor Air
A/TT1K( )-A12′ Copper Averaging 12′
A/TT1K( )-A24′ Copper Averaging 24′
A/TT1K( )-RA18″-PB S.S. Rigid Averaging 18″
A/TT1K( )-RA24″-PB S.S. Rigid Averaging 24″
A/TT1K( )-RA36″-PB S.S. Rigid Averaging 36″
A/TT1K( )-SP Stainless Steel Plate
A/TT1K( )-AP Aluminum Plate
A/TT1K( )-BP Bullet Probe
A/TT1K( )-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/TT1K( )-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/TT1K( )-BBS Brass Button Sensor
A/TT1K( )-SBS Stainless Steel Button Sensor
A/TT1K( )-PBS Plastic Button Sensor
A/TT1K( )-LTS-10′ Freezer Probe with 10′ Leads
A/TT1K( )-BO Transmitter Board Only
A/TUC2 Microprocessor LCD Display Temp
A/TUC2-Fan Microprocessor LCD Display Temp
Optional Potted TT Board (not available in Room and EH enclosures)
Matched 100 Ohm Temperature Transmitters
A/TTM100( )-R Room
-(DF) or (DC) LCD LCD option, add to part # above
A/TTM100( )-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/TTM100( )-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/TTM100( )-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/TTM100( )-S-GD Strap-On, 2-5″ Pipe
A/TTM100( )-O Outdoor Air
A/TTM100( )-A12′ Copper Averaging 12′
A/TTM100( )-A24′ Copper Averaging 24′
A/TTM100( )-SP Stainless Steel Plate
A/TTM100( )-BP Bullet Probe
Matched 1K Ohm Temperature Transmitters
A/TTM1K( )-R Room
-(DF) or (DC) LCD can be added to the Room Sensors above
A/TTM1K( )-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/TTM1K( )-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/TTM1K( )-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/TTM1K( )-S-GD Strap-On, 2-5″ Pipe
A/TTM1K( )-O Outdoor Air
A/TTM1K( )-A12′ Copper Averaging 12′
A/TTM1K( )-A24′ Copper Averaging 24′
A/TTM1K( )-SP Stainless Steel Plate
A/TTM1K( )-LTS-10′ Freezer Probe with 10′ Leads
Extreme High 100 & 1K Ohm Temperature Transmitters
A/TT100-HT( )-D( ) Duct (4″, 8″, 12″, 18″ )
A/TT100-HT( )-I( ) Immersion (2.5″, 4″, 6″ ) WITH Well
A/TT100-HT( )-10′ Remote Probe
A/TT1K-HT( )-D( ) Duct (4″, 8″, 12″, 18″ )
A/TT1K-HT( )-I( ) Immersion (2.5″, 4″, 6″ ) WITH Well
A/TT1K-HT( )-10′ Remote Probe
Extreme Low 100 & 1K Ohm Temperature Transmitters
A/TT100-LT( )-D( ) Duct (4″, 8″, 12″, 18″ )
A/TT100-LT( )-I( ) Immersion (2.5″, 4″, 6″ ) WITH Well
A/TT100-LT( )-10′ Remote Probe
A/TT100-LT( )-O Outdoor Air
A/TT1K-LT( )-D( ) Duct (4″, 8″, 12″, 18″ )
A/TT1K-LT( )-I( ) Immersion (2.5″, 4″, 6″ ) WITH Well
A/TT1K-LT( )-10′ Remote Probe
A/TT1K-LT( )-O Outdoor Air
Submersible Cryogenic Temperature Sensors and Transmitters
A/100-LTS-10′ 100 Ohm RTD Remote Probe w/10′ Lead
A/1K-LTS-10′ 1K Ohm RTD Remote Probe w/10′ Lead
A/TT1K-LTS-10′ Transmitter Remote Probe w/10′ Lead
A/TTM1K-LTS-10′ Matched Transmitter Remote Probe w/10′ Lead
A/Glycol Bottle Nalgene TM Bottle 4oz.
TUC2 Microprosessor based. Available with various sensor outputs.
A/TUC2 Microprocessor LCD Display Temp
A/TUC2-Fan Microprocessor LCD Display Temp
A/1.8K-R2 Room
A/1.8K-R2S Room w/ Setpoint
A/1.8K-R2O Room w/ Override
A/1.8K-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/1.8K-D( )-PB Duct (4″, 8″, 12″, 18″ )
A/1.8K-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/1.8K-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/1.8K-IM-2.5″-GD Immersion 2.5″ WITH Machined Well
A/1.8K-IM-4″-GD Immersion 4″ WITH Machined Well
A/1.8K-IM-6″-GD Immersion 6″ WITH Machined Well
A/1.8K-S-GD Strap-On, 2-5″ Pipe
A/1.8K-O Outdoor Air
A/1.8K-W Raw Sensor in plastic cup
A/1.8K-W-6′ Raw Sensor w/ 6′ Leads
A/1.8K-A8′-PB Copper Averaging 8′
A/1.8K-A12′-PB Copper Averaging 12′
A/1.8K-A24′-PB Copper Averaging 24′
-50′ and 100′ Averaging is available, Please call
A/1.8K-FA8′-PB Flexible Cable Averaging 8′
A/1.8K-FA12′-PB Flexible Cable Averaging 12′
A/1.8K-FA24′-PB Flexible Cable Averaging 24′
A/1.8K-RA18″-PB S.S. Rigid Averaging 18″
A/1.8K-RA24″-PB S.S. Rigid Averaging 24″
A/1.8K-RA36″-PB S.S. Rigid Averaging 36″
A/1.8K-SP Stainless Steel Plate
A/1.8K-AP Aluminum Plate
A/1.8K-BP Bullet Probe
A/1.8K-BP-20’Zip Bullet Probe, 20′ Zip Cord
A/1.8K-BP-6’CL2P Bullet Probe (4″, 8″, 12″, 18″) Plenum Wire
A/1.8K-BP-10’CL2P Bullet Probe (4″, 8″, 12″, 18″) Plenum Wire
A/1.8K-BP-20’CL2P Bullet Probe (4″, 8″, 12″, 18″) Plenum Wire
A/1.8K-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/1.8K-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/1.8K-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/1.8K-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/1.8K-BBS Brass Button Sensor
A/1.8K-SBS Stainless Steel Button Sensor
A/1.8K-PBS Plastic Button Sensor
A/1.8K-FRZ2″-30′ Freezer Remote Probe,30′ Leads
3K Thermisor
A/3K-R2 Room
A/3K-R2S Room w/ Setpoint
A/3K-R2O Room w/ Override
A/3K-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/3K-D( )-PB Duct (4″, 8″, 12″, 18″ )
Sensors of 24″, 36″, and 48″ are available
A/3K-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/3K-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/3K-IM-2.5″-GD Immersion 2.5″ WITH Machined Well
A/3K-IM-4″-GD Immersion 4″ WITH Machined Well
A/3K-IM-6″-GD Immersion 6″ WITH Machined Well
A/3K-S-GD Strap-On, 2-5″ Pipe
A/3K-O Outdoor Air
A/3K-W Raw Sensor in plastic cup
A/3K-W-6′ Raw Sensor w/ 6′ Leads
A/3K-A8′-PB Copper Averaging 8′
A/3K-A12′-PB Copper Averaging 12′
A/3K-A24′-PB Copper Averaging 24′
-50′ and 100′ Averaging is available, Please call
A/3K-FA8′-PB Flexible Cable Averaging 8′
A/3K-FA12′-PB Flexible Cable Averaging 12′
A/3K-FA24′-PB Flexible Cable Averaging 24′
A/3K-RA18″-PB S.S. Rigid Averaging 18″
A/3K-RA24″-PB S.S. Rigid Averaging 24″
A/3K-RA36″-PB S.S. Rigid Averaging 36″
A/3K-SP Stainless Steel Plate
A/3K-AP Aluminum Plate
A/3K-BP Bullet Probe
A/3K-BP-20’Zip Bullet Probe, 20′ Zip Cord
A/3K-BP-6’CL2P Bullet Probe (4″, 8″, 12″, 18″) Plenum Wire
A/3K-BP-10’CL2P Bullet Probe (4″, 8″, 12″, 18″) Plenum Wire
A/3K-BP-20’CL2P Bullet Probe (4″, 8″, 12″, 18″) Plenum Wire
A/3K-DO-( ) Duct without Box (4″, 8″, 12″, 18″ )
A/3K-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/3K-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/3K-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/3K-BBS Brass Button Sensor
A/3K-SBS Stainless Steel Button Sensor
A/3K-PBS Plastic Button Sensor
A/3K-FRZ2″-30′ Freezer Remote Probe,30′ Leads
A/CP-R2 Room
A/CP-R2S Room w/ Setpoint
A/CP-R2O Room w/ Override
A/CP-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/CP-D( )-PB Duct (4″, 8″, 12″, 18″ )
Sensors of 24″, 36″, and 48″ are available
A/CP-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/CP-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/CP-IM-2.5″-GD Immersion 2.5″ WITH Machined Well
A/CP-IM-4″-GD Immersion 4″ WITH Machined Well
A/CP-IM-6″-GD Immersion 6″ WITH Machined Well
A/CP-S-GD Strap-On, 2-5″ Pipe
A/CP-O Outdoor Air
A/CP-W Raw Sensor in plastic cup
A/CP-W-6′ Raw Sensor w/ 6′ Leads
A/CP-A8′-PB Copper Averaging 8′
A/CP-A12′-PB Copper Averaging 12′
A/CP-A24′-PB Copper Averaging 24′
-50′ and 100′ Averaging is available, Please call
A/CP-FA8′-PB Flexible Cable Averaging 8′
A/CP-FA12′-PB Flexible Cable Averaging 12′
A/CP-FA24′-PB Flexible Cable Averaging 24′
A/CP-RA18″-PB S.S. Rigid Averaging 18″
A/CP-RA24″-PB S.S. Rigid Averaging 24″
A/CP-RA36″-PB S.S. Rigid Averaging 36″
A/CP-SP Stainless Steel Plate
A/CP-AP Aluminum Plate
A/CP-BP Bullet Probe
A/CP-BP-20’Zip Bullet Probe, 20′ Zip Cord
A/CP-BP-6’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/CP-BP-10’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/CP-BP-20’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/CP-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/CP-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/CP-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/CP-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/CP-BBS Brass Button Sensor
A/CP-SBS Stainless Steel Button Sensor
A/CP-PBS Plastic Button Sensor
A/CP-FRZ2″-30′ Freezer Remote Probe,30′ Leads
AN Thermisor
A/AN-R2 Room
A/AN-R2S Room w/ Setpoint
A/AN-R2O Room w/ Override
A/AN-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/AN-D( )-PB Duct (4″, 8″, 12″, 18″ )
Sensors of 24″, 36″, and 48″ are available
A/AN-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/AN-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/AN-IM-2.5″-GD Immersion 2.5″ WITH Machined Well
A/AN-IM-4″-GD Immersion 4″ WITH Machined Well
A/AN-IM-6″-GD Immersion 6″ WITH Machined Well
A/AN-S-GD Strap-On, 2-5″ Pipe
A/AN-O Outdoor Air
A/AN-W Raw Sensor in plastic cup
A/AN-W-6′ Raw Sensor w/ 6′ Leads
n
A/AN-A8′-PB Copper Averaging 8′
A/AN-A12′-PB Copper Averaging 12′
A/AN-A24′-PB Copper Averaging 24′
-50′ and 100′ Averaging is available, Please call
A/AN-FA8′-PB Flexible Cable Averaging 8′
A/AN-FA12′-PB Flexible Cable Averaging 12′
A/AN-FA24′-PB Flexible Cable Averaging 24′
A/AN-RA18″-PB S.S. Rigid Averaging 18″
A/AN-RA24″-PB S.S. Rigid Averaging 24″
A/AN-RA36″-PB S.S. Rigid Averaging 36″
A/AN-SP Stainless Steel Plate
A/AN-AP Aluminum Plate
A/AN-BP Bullet Probe
A/AN-BP-20’Zip Bullet Probe, 20′ Zip Cord
A/AN-BP-6’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-BP-10’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-BP-20’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/AN-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-BBS Brass Button Sensor
A/AN-SBS Stainless Steel Button Sensor
A/AN-PBS Plastic Button Sensor
A/AN-FRZ2″-30′ Freezer Remote Probe,30′ Leads
20K Thermisor
A/20K-R2 Room
A/20K-R2S Room w/ Setpoint
A/20K-R2O Room w/ Override
A/20K-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/20K-D( )-PB Duct (4″, 8″, 12″, 18″ )
Sensors of 24″, 36″, and 48″ are available
A/20K-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/20K-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/20K-IM-2.5″-GD Immersion 2.5″ WITH Machined Well
A/20K-IM-4″-GD Immersion 4″ WITH Machined Well
A/20K-IM-6″-GD Immersion 6″ WITH Machined Well
A/20K-S-GD Strap-On, 2-5″ Pipe
A/20K-O Outdoor Air
A/20K-W Raw Sensor in plastic cup
A/20K-W-6′ Raw Sensor w/ 6′ Leads
A/20K-A8′-PB Copper Averaging 8′
A/20K-A12′-PB Copper Averaging 12′
A/20K-A24′-PB Copper Averaging 24′
-50′ and 100′ Averaging is available, Please call
A/20K-FA8′-PB Flexible Cable Averaging 8′
A/20K-FA12′-PB Flexible Cable Averaging 12′
A/20K-FA24′-PB Flexible Cable Averaging 24′
A/20K-RA18″-PB S.S. Rigid Averaging 18″
A/20K-RA24″-PB S.S. Rigid Averaging 24″
A/20K-RA36″-PB S.S. Rigid Averaging 36″
A/20K-SP Stainless Steel Plate
A/20K-AP Aluminum Plate
A/20K-BP Bullet Probe
A/20K-BP-20’Zip Bullet Probe, 20′ Zip Cord
A/20K-BP-6’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/20K-BP-10’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/20K-BP-20’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/20K-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/20K-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/20K-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/20K-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/20K-BBS Brass Button Sensor
A/20K-SBS Stainless Steel Button Sensor
A/20K-PBS Plastic Button Sensor
A/20K-FRZ2″-30′ Freezer Remote Probe,30′ Leads
100K Thermisor
A/100KS-R2 Room
A/100KS-R2S Room w/ Setpoint
A/100KS-R2O Room w/ Override
A/100KS-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/100KS-D( )-PB Duct (4″, 8″, 12″, 18″ )
Sensors of 24″, 36″, and 48″ are available
A/100KS-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/100KS-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/100KS-IM-2.5″-GD Immersion 2.5″ WITH Machined Well
A/100KS-IM-4″-GD Immersion 4″ WITH Machined Well
A/100KS-IM-6″-GD Immersion 6″ WITH Machined Well
A/100KS-S-GD Strap-On, 2-5″ Pipe
A/100KS-O Outdoor Air
A/100KS-W Raw Sensor in plastic cup
A/100KS-W-6′ Raw Sensor w/ 6′ Leads
A/100KS-A8′-PB Copper Averaging 8′
A/100KS-A12′-PB Copper Averaging 12′
A/100KS-A24′-PB Copper Averaging 24′
-50′ and 100′ Averaging is available, Please call
A/100KS-FA8′-PB Flexible Cable Averaging 8′
A/100KS-FA12′-PB Flexible Cable Averaging 12′
A/100KS-FA24′-PB Flexible Cable Averaging 24′
A/100KS-RA18″-PB S.S. Rigid Averaging 18″
A/100KS-RA24″-PB S.S. Rigid Averaging 24″
A/100KS-RA36″-PB S.S. Rigid Averaging 36″
A/100KS-SP Stainless Steel Plate
A/100KS-AP Aluminum Plate
A/100KS-BP Bullet Probe
A/100KS-BP-20’Zip Bullet Probe, 20′ Zip Cord
A/100KS-BP-6’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/100KS-BP-10’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/100KS-BP-20’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/100KS-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/100KS-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/100KS-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/100KS-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/100KS-BBS Brass Button Sensor
A/100KS-SBS Stainless Steel Button Sensor
A/100KS-PBS Plastic Button Sensor
A/100KS-FRZ2″-30′ Freezer Remote Probe,30′ Leads
2252 Thermisor
A/2252-R2 Room
A/2252-R2S Room w/ Setpoint
A/2252-R2O Room w/ Override
A/2252-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/2252-D( )-PB Duct (4″, 8″, 12″, 18″ )
Sensors of 24″, 36″, and 48″ are available
A/2252-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/2252-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/2252-IM-2.5″-GD Immersion 2.5″ WITH Machined Well
A/2252-IM-4″-GD Immersion 4″ WITH Machined Well
A/2252-IM-6″-GD Immersion 6″ WITH Machined Well
A/2252-S-GD Strap-On, 2-5″ Pipe
A/2252-O Outdoor Air
A/2252-W Raw Sensor in plastic cup
A/2252-W-6′ Raw Sensor w/ 6′ Leads
A/2252-A8′-PB Copper Averaging 8′
A/2252-A12′-PB Copper Averaging 12′
A/2252-A24′-PB Copper Averaging 24′
-50′ and 100′ Averaging is available, Please call
A/2252-FA8′-PB Flexible Cable Averaging 8′
A/2252-FA12′-PB Flexible Cable Averaging 12′
A/2252-FA24′-PB Flexible Cable Averaging 24′
A/2252-RA18″-PB S.S. Rigid Averaging 18″
A/2252-RA24″-PB S.S. Rigid Averaging 24″
A/2252-RA36″-PB S.S. Rigid Averaging 36″
A/2252-SP Stainless Steel Plate
A/2252-AP Aluminum Plate
A/2252-BP Bullet Probe
A/2252-BP-20’Zip Bullet Probe, 20′ Zip Cord
A/2252-BP-6’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/2252-BP-10’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/2252-BP-20’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/2252-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/2252-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/2252-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/2252-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/2252-BBS Brass Button Sensor
A/2252-SBS Stainless Steel Button Sensor
A/2252-PBS Plastic Button Sensor
A/2252-FRZ2″-30′ Freezer Remote Probe,30′ Leads
5K Thermisor
A/5K-R2 Room
A/5K-R2S Room w/ Setpoint
A/5K-R2O Room w/ Override
A/5K-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/5K-D( )-PB Duct (4″, 8″, 12″, 18″ )
Sensors of 24″, 36″, and 48″ are available
A/5K-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/5K-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/5K-IM-2.5″-GD Immersion 2.5″ WITH Machined Well
A/5K-IM-4″-GD Immersion 4″ WITH Machined Well
A/5K-IM-6″-GD Immersion 6″ WITH Machined Well
A/5K-S-GD Strap-On, 2-5″ Pipe
A/5K-O Outdoor Air
A/5K-W Raw Sensor in plastic cup
A/5K-W-6′ Raw Sensor w/ 6′ Leads
A/5K-A8′-PB Copper Averaging 8′
A/5K-A12′-PB Copper Averaging 12′
A/5K-A24′-PB Copper Averaging 24′
-50′ and 100′ Averaging is available, Please call
A/5K-FA8′-PB Flexible Cable Averaging 8′
A/5K-FA12′-PB Flexible Cable Averaging 12′
A/5K-FA24′-PB Flexible Cable Averaging 24′
A/5K-RA18″-PB S.S. Rigid Averaging 18″
A/5K-RA24″-PB S.S. Rigid Averaging 24″
A/5K-RA36″-PB S.S. Rigid Averaging 36″
A/5K-SP Stainless Steel Plate
A/5K-AP Aluminum Plate
A/5K-BP Bullet Probe
A/5K-BP-20’Zip Bullet Probe, 20′ Zip Cord
A/5K-BP-6’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/5K-BP-10’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/5K-BP-20’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/5K-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/5K-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/5K-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/5K-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/5K-BBS Brass Button Sensor
A/5K-SBS Stainless Steel Button Sensor
A/5K-PBS Plastic Button Sensor
A/5K-FRZ2″-30′ Freezer Remote Probe,30′ Leads
CSI Thermisor
A/CSI-R2 Room
A/CSI-R2S Room w/ Setpoint
A/CSI-R2O Room w/ Override
A/CSI-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/CSI-D( )-PB Duct (4″, 8″, 12″, 18″ )
Sensors of 24″, 36″, and 48″ are available
A/CSI-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/CSI-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/CSI-IM-2.5″-GD Immersion 2.5″ WITH Machined Well
A/CSI-IM-4″-GD Immersion 4″ WITH Machined Well
A/CSI-IM-6″-GD Immersion 6″ WITH Machined Well
A/CSI-S-GD Strap-On, 2-5″ Pipe
A/CSI-O Outdoor Air
A/CSI-W Raw Sensor in plastic cup
A/CSI-W-6′ Raw Sensor w/ 6′ Leads
A/CSI-A8′-PB Copper Averaging 8′
A/CSI-A12′-PB Copper Averaging 12′
A/CSI-A24′-PB Copper Averaging 24′
-50′ and 100′ Averaging is available, Please call
A/CSI-FA8′-PB Flexible Cable Averaging 8′
A/CSI-FA12′-PB Flexible Cable Averaging 12′
A/CSI-FA24′-PB Flexible Cable Averaging 24′
A/CSI-RA18″-PB S.S. Rigid Averaging 18″
A/CSI-RA24″-PB S.S. Rigid Averaging 24″
A/CSI-RA36″-PB S.S. Rigid Averaging 36″
A/CSI-SP Stainless Steel Plate
A/CSI-AP Aluminum Plate
A/CSI-BP Bullet Probe
A/CSI-BP-20’Zip Bullet Probe, 20′ Zip Cord
A/CSI-BP-6’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/CSI-BP-10’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/CSI-BP-20’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/CSI-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/CSI-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/CSI-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/CSI-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/CSI-BBS Brass Button Sensor
A/CSI-SBS Stainless Steel Button Sensor
A/CSI-PBS Plastic Button Sensor
A/CSI-FRZ2″-30′ Freezer Remote Probe,30′ Leads
AN-BC Thermisor
A/AN-BC-R2 Room
A/AN-BC-R2S Room w/ Setpoint
A/AN-BC-R2O Room w/ Override
A/AN-BC-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/AN-BC-D( )-PB Duct (4″, 8″, 12″, 18″ )
Sensors of 24″, 36″, and 48″ are available
A/AN-BC-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/AN-BC-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/AN-BC-IM-2.5″-GD Immersion 2.5″ WITH Machined Well
A/AN-BC-IM-4″-GD Immersion 4″ WITH Machined Well
A/AN-BC-IM-6″-GD Immersion 6″ WITH Machined Well
A/AN-BC-S-GD Strap-On, 2-5″ Pipe
A/AN-BC-O Outdoor Air
A/AN-BC-W Raw Sensor in plastic cup
A/AN-BC-W-6′ Raw Sensor w/ 6′ Leads
A/AN-BC-A8′-PB Copper Averaging 8′
A/AN-BC-A12′-PB Copper Averaging 12′
A/AN-BC-A24′-PB Copper Averaging 24′
-50′ and 100′ Averaging is available, Please call
A/AN-BC-FA8′-PB Flexible Cable Averaging 8′
A/AN-BC-FA12′-PB Flexible Cable Averaging 12′
A/AN-BC-FA24′-PB Flexible Cable Averaging 24′
A/AN-BC-RA18″-PB S.S. Rigid Averaging 18″
A/AN-BC-RA24″-PB S.S. Rigid Averaging 24″
A/AN-BC-RA36″-PB S.S. Rigid Averaging 36″
A/AN-BC-SP Stainless Steel Plate
A/AN-BC-AP Aluminum Plate
A/AN-BC-BP Bullet Probe
A/AN-BC-BP-20’Zip Bullet Probe, 20′ Zip Cord
A/AN-BC-BP-6’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-BC-BP-10’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-BC-BP-20’CL2P Bullet Probe (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-BC-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/AN-BC-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-BC-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-BC-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/AN-BC-BBS Brass Button Sensor
A/AN-BC-SBS Stainless Steel Button Sensor
A/AN-BC-PBS Plastic Button Sensor
A/AN-BC-FRZ2″-30′ Freezer Remote Probe,30′ Leads
10KS Thermisor
A/10KS-R2 Room
A/10KS-R2S Room w/ Setpoint
A/10KS-R2O Room w/ Override
A/10KS-R2SO Room w/ Setpoint & Override
-RJ4 or RJ6 or RS232 Communication Jack options
-(DF) or (DC) LCD LCD option, add to part # above
A/10KS-D( )-PB Duct (4″, 8″, 12″, 18″ )
Sensors of 24″, 36″, and 48″ are available
A/10KS-I( )-NWGD Immersion (2.5″, 4″, 6″ ) NO Well
A/10KS-I( )-GD Immersion (2.5″, 4″, 6″ ) WITH Well
A/10KS-IM-2.5″-GD Immersion 2.5″ WITH Machined Well
A/10KS-IM-4″-GD Immersion 4″ WITH Machined Well
A/10KS-IM-6″-GD Immersion 6″ WITH Machined Well
A/10KS-S-GD Strap-On, 2-5″ Pipe
A/10KS-O Outdoor Air
A/10KS-W Raw Sensor in plastic cup
A/10KS-W-6′ Raw Sensor w/ 6′ Leads
A/10KS-A8′-PB Copper Averaging 8′
A/10KS-A12′-PB Copper Averaging 12′
A/10KS-A24′-PB Copper Averaging 24′
-50′ and 100′ Averaging is available, Please call
A/10KS-FA8′-PB Flexible Cable Averaging 8′
A/10KS-FA12′-PB Flexible Cable Averaging 12′
A/10KS-FA24′-PB Flexible Cable Averaging 24′
A/10KS-RA18″-PB S.S. Rigid Averaging 18″
A/10KS-RA24″-PB S.S. Rigid Averaging 24″
A/10KS-RA36″-PB S.S. Rigid Averaging 36″
A/10KS-SP Stainless Steel Plate
A/10KS-AP Aluminum Plate
A/10KS-BP Bullet Probe
A/10KS-BP-20’Zip Bullet Probe, 20′ Zip Cord
A/10KS-BP-6’CL2P Bullet Probe (4″, 8″, 12″, 18″ )
A/10KS-BP-10’CL2P Bullet Probe (4″, 8″, 12″, 18″ )
A/10KS-BP-20’CL2P Bullet Probe (4″, 8″, 12″, 18″ )
A/10KS-DO ( ) Duct without Box (4″, 8″, 12″, 18″ )
A/10KS-DO ( )6’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/10KS-DO ( )10’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/10KS-DO ( )20’CL2P Duct w/o Box (4″, 8″, 12″, 18″ )Plenum Wire
A/10KS-BBS Brass Button Sensor
A/10KS-SBS Stainless Steel Button Sensor
A/10KS-PBS Plastic Button Sensor
A/10KS-FRZ2″-30′ Freezer Remote Probe,30′ Leads
5% Relative Humidity Transmitters
A/RH5-R Room (Delta housing)
A/RH5-R2 Room
A/RH5-R2S Room w/Setpoint Adjust
A/RH5-R2O Room w/Override
A/RH5-R2SO Room w/setpoint & Override
A/RH5-D Duct
A/RH5-O Outdoor Air
A/RH5-SP Stainless Steel Plate
A/RH5-R-LCD Room w/LCD
A/TUCH2-5% Microprocessor LCD Display Temp/RH
3% Relative Humidity Transmitters
A/RH3-R Room (Delta housing)
A/RH3-R2 Room
A/RH3-R2S Room w/Setpoint Adjust
A/RH3-R2O Room w/Override
A/RH3-R2SO Room w/setpoint & Override
A/RH3-D Duct
A/RH3-O Outdoor Air
A/RH3-SP Stainless Steel Plate
A/RH3-R-LCD Room w/LCD
A/TUCH2-3% Microprocessor LCD Display Temp/RH
2% Relative Humidity Transmitters
A/RH2-R Room (Delta housing)
A/RH2-R2 Room
A/RH2-D Duct
A/RH2-O Outdoor Air
A/RH2-SP Stainless Steel Plate
A/RH2-R-LCD Room w/LCD
A/TUCH2-2% Microprocessor LCD Display Temp/RH
1% Relative Humidity Transmitters
A/RH1-R (Choose 20% Range) Room (Delta housing)
A/RH1-R2 (Choose 20% Range) Room
A/RH1-D (Choose 20% Range) Duct
A/RH1-O (Choose 20% Range) Outdoor Air
SUNSHIELD with or without RH or Temperature
A/RH2-O-SUN Room with Sunshield
A/RH2-T-O-SUN Outdoor Air with Temperature and Sunshield
A/RH2-TT1K-O-SUN Outdoor Air with TT and Sunshield
A/T-O-SUN Outdoor Air Temperature with Sunshield
A/TT1K-O-SUN Outdoor Air TT and Sunshield
100K
5% Temp/RH Combination Transmitters
A/RH5-( t )-R2 Room
A/RH5-( t )-R2S Room w/Setpoint Adjust
A/RH5-( t )-R2O Room w/Override
A/RH5-( t )-R2SO Room w/setpoint & Override
A/RH5-( t )-D Duct
A/RH5-( t )-O Outdoor Air
A/RH5-( t )-SP Stainless Steel Plate
A/TUCH2-5% Microprocessor LCD Display Temp/RH
3% Temp/RH Combination Transmitters
A/RH3-( t )-R2 Room
A/RH3-( t )-R2S Room w/Setpoint Adjust
A/RH3-( t )-R2O Room w/Override
A/RH3-( t )-R2SO Room w/setpoint & Override
A/RH3-( t )-D Duct
A/RH3-( t )-O Outdoor Air
A/RH3-( t )-SP Stainless Steel Plate
A/TUCH2-3% Microprocessor LCD Display Temp/RH
2% Temp/RH Combination Transmitters
A/RH2-( t )-R2 Room
A/RH2-( t )-D Duct
A/RH2-( t )-O Outdoor Air
A/RH2-( t )-SP Stainless Steel Plate
A/TUCH2-2% Microprocessor LCD Display Temp/RH
1% Temp/RH Combination Transmitters
A/RH1-( t )-R2 Room
A/RH1-( t )-D Duct
A/RH1-( t )-O Outdoor Air
5% Humidity Transmitter /Temperature Transmitter Combinations
A/RH5-TT100( )-R2 Room
A/RH5-TT100( )-D Duct
A/RH5-TT100( )-O Outdoor Air
A/RH5-TT1K( )-R2 Room
A/RH5-TT1K( )-D Duct
A/RH5-TT1K( )-O Outdoor Air
A/TUCH2-5% Microprocessor LCD Display Temp/RH
3% Humidity Transmitter /Temperature Transmitter Combinations
A/RH3-TT100( )-R2 Room
A/RH3-TT100( )-D Duct
A/RH3-TT100( )-O Outdoor Air
A/RH3-TT1K( )-R2 Room
A/RH3-TT1K( )-D Duct
A/RH3-TT1K( )-O Outdoor Air
A/TUCH2-3% Microprocessor LCD Display Temp/RH
2% Humidity Transmitter /Temperature Transmitter Combinations
A/RH2-TT100( )-R2 Room
A/RH2-TT100( )-D Duct
A/RH2-TT100( )-O Outdoor Air
A/RH2-TT1K( )-R2 Room
A/RH2-TT1K( )-D Duct
A/RH2-TT1K( )-O Outdoor Air
A/TUCH2-2% Microprocessor LCD Display Temp/RH
1% Humidity Transmitter /Temperature Transmitter Combinations
A/RH1-TT100( )-R2 Room
A/RH1-TT100( )-D Duct
A/RH1-TT100( )-O Outdoor Air
A/RH1-TT1K( )-R2 Room
A/RH1-TT1K( )-D Duct
A/RH1-TT1K( )-O Outdoor Air
Relative Humidity Calibration Certificates
A/3PT NIST CERT 3 Point Calibration Certificate for RH
A/5PT NIST CERT 5 Point Calibration Certificate for RH
Temperature Calibration Certificates
Matched Temperature 3 Point Calibration Certificate for TTM
Enthalpy/Transmitters
A/DIFF-ENT 28 BTU’s or 75F Trip Point Outdoor Enthalpy Control
(Meets Ashrae 90.1 spec)
A/DIFF-ENT-24 24 BTU’s or 70F Trip Point Outdoor Enthalpy Control
A/ENT 4-20mA Loop Powered Enthalpy Transmitter(0 to 50 BTU’s)
Pressure Transmitters
A/MLP Low Differential Pressure Transmitter
A/LP-( )-( ) Low Differential Pressure Transmitter
A/LP2-( )-( ) Low Differential Pressure Transmitter
A/LP-( )-( )-E Low Differential Pressure Transmitter,
Enclosed Terminals
A/LP2-( )-( )-LCD Low Differential Pressure Transmitter, w/LCD
A/DP2-( )-( ) Field Selectable Low Differential
Pressure Transmitter
A/DP2(0-0.1″)/(+/- 0.1″) A/DP2-(0 to 0.1″ ) or (+/- 0.1″ )
A/DP2-( )-( )-PT A/DP2 with Pitot Tube
A/DP2(0-0.1″)/(+/- 0.1″)-PTA/DP2-(0 to 0.1″ ) or (+/- 0.1″ ) w Pitot Tube
Pitot Tubes
PT 3″ Pitot Tube w/1 sensing point, 3 5/32″ Length
PT 5.2″ Pitot Tube w/2 sets of sensing points,
5 13/32″ Length
PT 7.5″ Pitot Tube w/3 sets of sensing points,
7 21/32″ Length
PT 9.7″ Pitot Tube w/4 sets of sensing points,
9 29/32″ Length
SPT 3.5″ Static Pressure Tube, 3.5″
SPT 8.0″ Static Pressure Tube, 8.0″
VPT Velocity Pitot Tube
A/10′ Tube 10′ Tubing, medical grade flexible Polyvinyl Chlo
Pressure Port Pickup
A/R-PUP Infinity Room housing Pickup Port
A/SP-PUP Stainless Steel plate Pickup Port
A/O-PUP-V Outside Pickup Port
A/O-PUP-H
Gage Pressure
GP( )-20 4 to 20 mA Gage Pressure Transmitters
GP( )-20 Bi-Directional 4 to 20 mA Gage
Pressure Transmitters
GP( )-20-N4 4 to 20 mA Gage Pressure Transmitters
in NEMA 4 Housing
Wet/Wet Pressure
629( )-( ) Wet to Wet Differential Pressure Transducer
629( )-( )-D Wet to Wet Differential Pressure Transducer
w/LED Display
629( )-( )-3V Wet to Wet Differential Pressure Transducer
w/3-Valve Manifold
WP( )-( ) Wet to Wet Differential Pressure Transducer
WP-B( )-( ) Bi-Directional Wet to Wet Differential Pressure Transducer
WP( )-( )3V Wet to Wet Differential Pressure Transducer w/3-Valve Manifold
Pressure Switches
AFS-222 0.07 to 12″ H2O w/ Automatic Reset
AFS-262 0.07 to 2″ H2O w/ Automatic Reset
AFS-460 0.06 to 12″ H2O w/ Manual Reset
DBL-205 Setpoint (0.16 to 0.4” w.c) (1) Set SPDT Contact
DBL-205A Setpoint (0.16 to 0.8” w.c) (1) Set SPDT Contact
DBL-205B Setpoint (0.20 to 2.0” w.c) (1) Set SPDT Contact
DBL-205D Setpoint (0.80 to 4.0” w.c) (1) Set SPDT Contact
DBL-205E Setpoint (2.0 to 10.0” w.c) (1) Set SPDT Contact
DBL-205L Setpoint (0.08 to 0.8” w.c.) (1) Set SPDT Contac
DBZ-06 Mounting Kit (2) Pitots, Grommets & 6.5′ tubing
Go/No Go
A/MCS Fixed Trip Point Current Switch (Solid-Core)
A/MSCS Fixed Trip Point Current Switch (Split-Core)
Adjustable
A/MCS-A Adjustable Trip Point Current Switch (Solid-Core
A/MSCS-A Adjustable Trip Point Current Switch (Split-Core)
Current Switches – Solid Core
A/CS 0.5A Trip, 0-250 Amp Operating Range, N/O
A/CS-L 0.2A Trip, 0-250 Amp Operating Range, N/O
A/CSX 1.0A Trip, 0-250 Amp Operating Range, Normally Closed
A/CSX-L 0.5A Trip, 0-250 Amp Operating Range, Normally Closed
Current Switches – Split Core
A/SCS 2.5A Trip, 0-200 Amp Operating Range, N/O
A/SCS-L 1.5A Trip, 0-200 Amp Operating Range, N/O
A/SCSX 2.5A Trip, 0-250 Amp Operating Range, Normally Closed
Adjustable Current Switches – Solid Core
A/ACS 1.0-250A Trip, 0-250 Amp Operating Range, N/
A/ACS-L 0.5-250A Trip, 0-250 Amp Operating Range, N/
A/ACSX 1.0-250A Trip, 0-250 Amp Operating Range, Normally Closed
Adjustable Current Switches – Split Core
A/ASCS 3.0 – 200A Trip, 0-200 Amp Operating Range,
A/ASCS-L 2.0 – 200A Trip, 0-200 Amp Operating Range,
A/ASCSX 3.0 – 250A Trip, 0-250 Amp Operating Range,
A/ASCSX-L 2.5 – 250A Trip, 0-250 Amp Operating Range,
Current Transmitter – Solid Core
A/CTA-5 4-20mA output, 0-5 Amp Fixed output
A/CTA-50 4-20mA output, 0-10/0-20/0-50 Amps
A/CTA-250 4-20mA output, 0-100/0-200/0-250 Amps
Current Transmitter – Split Core
A/SCTA-5 4-20mA output, 0-5 Amp Fixed output
A/SCTA-50 4-20mA output, 0-10/0-20/0-50 Amps
A/SCTA-200 4-20mA output, 0-100/0-150/0-200 Amps
Current Transmitter – Solid Core, TRUE RMS
A/CTA-50-VFD 4-20mA output, 0-10/0-20/0-50 Amps
A/CTA-250-VFD 4-20mA output, 0-100/0-200/0-250 Amps
Current Transmitter – Split Core, TRUE RMS
A/SCTA-5-VFD 4-20mA output, 0-5 Amp Fixed output
A/SCTA-50-VFD 4-20mA output, 0-10/0-20/0-50 Amps
A/SCTA-200-VFD 4-20mA output, 0-100/0-150/0-200 Amps
Current Transmitter (Voltage Output) – Solid Core
A/CTE-50 0-5VDC output, 0-10/0-20/0-50 Amps
A/CTE-250 0-5VDC output, 0-100/0-200/0-250 Amps
A/CTV-50 0-10VDC output, 0-10/0-20/0-50 Amps
A/CTV-250 0-10VDC output, 0-100/0-200/0-250 Amps
Current Transmitter (Voltage Output) – Split Core
A/SCTE-50 0-5VDC output, 0-10/0-20/0-50 Amps
A/SCTE-250 0-5VDC output, 0-100/0-200/0-250 Amps
A/SCTV-50 0-10VDC output, 0-10/0-20/0-50 Amps
A/SCTV-250 0-10VDC output, 0-100/0-200/0-250 Amps
Command Relays with Status LED(Compatible with any ACI current switch /transmitter)
A/CR-DC-5A SPDT, 5A(NO)/2A(NC) @250VAC, 5A(NO)/3A(NC) @125VAC, 23-31.2 VDC Coils
A/CR-DC-12A SPDT, 12A@250VAC, 12A @ 30VDC, Status LED, 23-31.2 VDC Coils
A/CR-12DC-12A SPDT, 12A@250VAC, 12A @ 30VDC, Status LED, 10-15.6 VDC Coils
A/CR-24AC-10A SPDT, 10A@250VAC, 10A @ 30VDC, Status LED, 16-26.4 VAC Coil
A/CR-115AC-8A SPDT, 8A@250VAC, 8A @ 30VDC, Status LED, 80-132 VAC Coil
A/CR-230AC-8A SPDT, 8A@250VAC, 8A @ 30VDC, Status LED, 165-264 VAC Coil
Gas / Smoke Detectors Carbon Dioxide
ESENSE-R Room, no display, 0-10 VDC or 4-20mA output
ESENSE-R-LCD Room with display, 0-10 VDC or 4-20mA output
ESENSE-R-5 Room, no display, 0-5VDC or 4-20mA output
ESENSE-R-5-LCD Room, with display, 0-5VDC or 4-20mA output
ESENSE-RE European Room, no display, 0-10 VDC or 4-20mA
ESENSE-RE-LCD European Room, with display, 0-10 VDC or 4-20mA
ESENSE-RE-5 European Room, no display, 0-5 VDC or 4-20mA
ESENSE-RE-5-LCD European Room, with display, 0-5 VDC or 4-20mA
ESENSE-D Duct, 0-10 VDC or 4-20mA output
ESENSE-D-LCD Duct, with LCD, 0-10 VDC or 4-20mA output
ESENSE-D-5 Duct, 0-5 VDC or 4-20mA output
ESENSE-D-5-LCD Duct, with LCD, 0-5 VDC or 4-20mA output
ESENSE-IP54 Industrial Room, 0-10 VDC or 4-20mA
ESENSE-IP54-LCD Industrial Room, with LCD, 0-10 VDC or 4-20mA
ESENSE-IP54-5 Industrial Room, 0-5 VDC or 4-20mA
ESENSE-IP54-5-LCD Industrial Room, with LCD, 0-5 VDC or 4-20mA
ESENSE-IP50 In Duct style with dual outputs, 0-10 VDC and 4-20mA
ESENSE-OUTSIDE Heated Outside Sensors, 0-10 VDC and 4-20mA
ASENSE-R Room, 0-10 VDC and 4-20mA
ASENSE-R-REL Room, 0-10 VDC and 4-20mA + Relay
ASENSE-R-LCD Room, 0-10 VDC and 4-20mA, LCD
ASENSE-R-LCD-REL Room, 0-10 VDC and 4-20mA, LCD + Relay
ASENSE-R-5 Room, 0-5 VDC and 4-20mA
ASENSE-R-5-REL Room, 0-5 VDC and 4-20mA + Relay
ASENSE-R-5-LCD Room, 0-5 VDC and 4-20mA, LCD
ASENSE-R-5-LCD-REL Room, 0-5 VDC and 4-20mA, LCD + Relay
ASENSE-D Duct, 0-10 VDC and 4-20mA
ASENSE-D-REL Duct, 0-10 VDC and 4-20mA + Relay
ASENSE-D-LCD Duct, 0-10 VDC and 4-20mA, LCD
ASENSE-D-LCD-REL Duct, 0-10 VDC and 4-20mA, LCD + Relay
ASENSE-D-5 Duct, 0-5 VDC and 4-20mA
ASENSE-D-5-REL Duct, 0-5 VDC and 4-20mA + Relay
ASENSE-D-5-LCD Duct, 0-5 VDC and 4-20mA, LCD
ASENSE-D-5-LCD-REL Duct, 0-5 VDC and 4-20mA, LCD + Relay
ASENSE-IP54 Industrial Room, 0-10 VDC and 4-20mA
ASENSE-IP54-REL Industrial Room, 0-10 VDC and 4-20mA + Relay
ASENSE-IP54-LCD Industrial Room, 0-10 VDC and 4-20mA, LCD
ASENSE-IP54-LCD-REL Industrial Room, 0-10 VDC and 4-20mA, LCD + Relay
ASENSE-IP54-5 Industrial Room, 0-5 VDC and 4-20mA
ASENSE-IP54-5-REL Industrial Room, 0-5 VDC and 4-20mA + Relay
ASENSE-IP54-5-LCD Industrial Room, 0-5 VDC and 4-20mA, LCD
ASENSE-IP54-5-LCD-REL Industrial Room, 0-5 VDC and 4-20mA, LCD + Relay
ASENSE-OUTSIDE Heated Outside Sensors, 0-10 VDC and 4-20mA
ASENSE-OUTSIDE-REL Heated Outside Sensors, 0-10 VDC and 4-20mA + Relay
CO2-010-R Room, CO2 Transmitter (0-10VDC only)
CO2-010-R-L Room, LED CO2 Transmitter (0-10VDC only)
CO2-010-D Duct, CO2 Transmitter (0-10VDC only)
Analog CO2 Transmitter w/Relay, 0-10VDC or 4-20mA output
CO2-VEN-R-W Room, White Enclosure
CO2-VEN-R-W-5 Room, White Enclosure, 05VDC Output
CO2-VEN-R-B Room, Black Enclosure
CO2-VEN-RO-W Room with Override, White Enclosure
CO2-VEN-RSO-W Room with Setpoint and Override, White Enclosure
CO2-VEN-D-B Duct, Black Enclosure
CO2-VEN-D-LCD-B Duct, Black Enclosure w/LCD
CO2-VEN-R-LCD-W Room, White Enclosure, w/LCD
CO2-VEN-R-LCD-B Room, Black Enclosure, w/LCD
CO2-VEN-R-RHT-W Room, CO2, RH, Temp, w/White Encl.
CO2-VEN-R-RHT-LCD-W Room, CO2, RH, Temp, wLCD, White Encl.
CO2-VEN-R-RHT-LCD-B Room, CO2, RH, Temp, wLCD, Black Encl.
CO2-VEN-R-W-BAC Room mount with BACnet, no display, white enclosure
CO2-VEN-R-LCD-W-BAC Room mount with BACnet, display, white enclosure
CO2 Outdoor Box CO2 Outdoor Box for VEN Series
CO2-DC-R-W Room, Dual Channel, CO2
CO2-DC-R-LCD-W Room w/LCD, Dual Channel, CO2
CO2-DC-R-RHT-LCD-W Room w/LCD, Dual Channel, CO2/RH/T
CO2-R-REL-2K Room, 0-2000ppm, w/Relay
CO2-R-REL-5K Room, 0-5000ppm, w/Relay
Carbon Monoxide Sensors
CO-R Room, CO
CO-R-4X Room, w/NEMA 4X ENC, CO
CO-R-4X-D Room, w/NEMA 4X ENC, LCD, CO
CO-R-RB-D Room, LCD, Relay, and Buzzer Alarm
CO-R-4X-RB-D Room, LCD, Relay, and Buzzer Alarm, $X
CO-D Duct w/ Pitot Tube
CO-D-RB-D Duct w/ Pitot Tube, LCD, Relay & Buzzer
Nitrogen Dioxide
NO2-R Room, NO2
NO2-R-4X Room, Nema 4X, NO2
NO2-R-4X-RB-D Room, LCD, Relay, Nema 4X, NO2
NO2-R-RB-D Room, LCD, Relay, Buzzer, NO2
NO2-D Duct, NO2
NO2-D-RB-D Duct, LCD, Relay, Buzzer, NO2
CTS
CTS-M5130X-Q000000 Oxygen 0-25% Electrochemical Gas Transmitter no rela
CTS-M5130X-Q0R0000 Oxygen 0-25% Electrochemical Gas Transmitter 2 relay
CTS-M5190X-Q000000 Nitric Oxide 0-100 ppm Electrochemical Gas Transmitte
CTS-M5190X-Q0R0000 Nitric Oxide 0-100 ppm Electrochemical Gas Transmitte
CTS-M5220X-Q000000 Ammonia 0-50 ppm Electrochemical Gas Transmitter no
CTS-M5220X-Q0R0000 Ammonia 0-50 ppm Electrochemical Gas Transmitter 2
Options Duct mount enclosure w/pitot tubes
NEMA 4x enclosure
2 x SPDT Relay and Buzzer
Conformal Coating
Q5
Q5-CH3C0-100L-0-X Acetone, Catalytic Bead, 0-100% LEL
Q5-NH3-100P-0-X Ammonia, Electrochemical, 0-100 ppm
Q5-NH3-1000P-0-X Ammonia, Electrochemical, 0-1000 ppm
Q5-ASH3-1P-0-X Arsine, Electrochemical, 0-1 ppm
Q5-C6H6-100L-0-X Benzene, Catalytic Bead, 0-100% LEL
Q5-C4H10-100L-0-X Iso-Butane, Catalytic Bead, 0-100% LEL
Q5-BUTAN-100L-0-X Butanol, n-Butane, Catalytic Bead, 0-100% LEL
Q5-CO2-5000P-0-X Carbon Dioxide, Infrared, 0-5000 ppm
Q5-CO2-5V-0-X Carbon Dioxide, Infrared, 0-5% VOL
Q5-CO2-20V-0-X Carbon Dioxide, Infrared, 0-20% VOL
Q5-CO2-100V-0-X Carbon Dioxide, Infrared, 0-100% VOL
Q5-CO-250P-0-X Carbon Monoxide, Electrochemical, 0-250 ppm
Q5-CO-1000P-0-X Carbon Monoxide, Electrochemical, 0-1000 ppm
Q5-CL2-5P-0-X Chlorine, Electrochemical, 0-5 ppm
Q5-CLO2-2P-0-X Chlorine Dioxide, electrochemical, 0-2 ppm
Q5-GENL-100L-0-X Combustible (specify type), Catalytic Bead, 0-100% LEL
Q5-B2H6-2P-0-X Diborane, Electrochemical, 0-2 ppm
Q5-C2H4-100L-0-X Ethylene, Catalytic Bead, 0-100% LEL
Q5-ETO-20P-0-X Ethylene Oxide, Electrochemical, 0-20 ppm
Q5-GEH4-2P-0-X Germane, electrochemical, 0-2 ppm
Q5-H2-1000P-0-X Hydrogen, Electrochemical, 0-1000 ppm
Q5-H2-2000P-0-X Hydrogen, Electrochemical, 0-2000 ppm
Q5-H2-100L-0-X Hydrogen, Catalytic Bead, 0-100% LEL
Q5-HBR-30P-0-X Hydrogen Bromide, Electrochemical, 0-30 ppm
Q5-HCL-30P-0-X Hydrogen Chloride, Electrochemical, 0-30 ppm
Q5-HCN-50P-0-X Hydrogen Cyanide, Electrochemical, 0-50 ppm
Q5-H2S-25P-0-X Hydrogen Sulphide, Electrochemical, 0-25 ppm
Q5-H2S-100P-0-X Hydrogen Sulphide, Electrochemical, 0-100 ppm
Q5-CH4-100L-0-X Methane, Catalytic Bead, 0-100% LEL
Q5-CH3OH-100L-0-X Methanol, Catalytic Bead, 0-100% LEL
Q5-NO-100P-0-X Nitric Oxide, Electrochemical, 0-100 ppm
Q5-NO2-10P-0-X Nitrogen Dioxide, Electrochemical, 0-10 ppm
Q5-O2-25V-0-X Oxygen, Electrochemical, 0-25% VOL
Q5-O3-1P-0-X Ozone, Electrochemical, 0-1 ppm
Q5-C5H12-100L-0-X Iso-Pentane, Catalytic Bead, 0-100% LEL
Q5-PH3-1P-0-X Phosphine, Electrochemical, 0-1 ppm
Q5-PH3-5P-0-X Phosphine, Electrochemical, 0-5 ppm
Q5-C3H8-100L-0-X Propane, Catalytic Bead, 0-100% LEL
Q5-SIH4-50P-0-X Silane, Electrochemical, 0-50 ppm
Q5-SO2-6P-0-X Sulphur Dioxide, Electrochemical, 0-6 ppm
Enclosure Type
Enclosure, Standard
Enclosure w/Pump-Thru Cap Kit
Enclosure w/Splash Guard Kit
Enclosure w/Duct Mount Kit
QIRF
QIRF-026X-0 R11 Infra-Red Freon Sensor 0-1000 ppm
QIRF-028X-0 R 22 Infra-Red Freon Sensor 0-1000 ppm
QIRF-123X-0 R123 Infra-Red Freon Sensor 0-100 ppm
QIRF-030X-0 R134a Infra-Red Freon Sensor 0-1000 ppm
QIRF-114X-0 R114 Infra-Red Freon Sensor 0-1000 ppm
QIRF-404X-0 R404a Infra-Red Freon Sensor 0-1000 ppm
QIRF-407X-0 R407c Infra-Red Freon Sensor 0-1000 ppm
QIRF-410X-0 R410a Infra-Red Freon Sensor 0-1000 ppm
QIRF-427X-0 R427a Infra-Red Freon Sensor 0-1000 ppm
QIRF-438X-0 R438a Infra-Red Freon Sensor 0-1000 ppm
QIRF-507X-0 R507a Infra-Red Freon Sensor 0-1000 ppm
QTS
QTS-17101X-S000000 Methane 0-100% LEL Class 1 Div 1
QTS-17111X-S000000 Acetylene 0-100% LEL Class 1 Div 1
QTS-17121X-S000000 Ethane 0-100% LEL Class 1 Div 1
QTS-17131X-S000000 Propane 0-100% LEL Class 1 Div 1
QTS-17141X-S000000 Butane 0-100% LEL Class 1 Div 1
QTS-17151X-S000000 Pentane 0-100% LEL Class 1 Div 1
QTS-17161X-S000000 Octane 0-100% LEL Class 1 Div 1
QTS-17171X-S000000 Hydrogen 0-100% LEL Class 1 Div 1
QTS-17181X-S000000 Gasoline 0-100% LEL Class 1 Div 1
Options
Protective Sensor Guard
Remote Mount Calibration
Duct Mount
Conformal Coating
Non-Standard Calibration
Special (Consult Factory)
CTS-M17 Nema 1 Combustible
CTS-M1710X-Q000000 Methane 0-100% LEL no relays
CTS-M1710X-Q0R0000 Methane 0-100% LEL with 2 relays
CTS-M1730X-Q000000 Propane 0-100% LEL no relays
CTS-M1730X-Q0R0000 Propane 0-100% LEL with 2 relays
QTS-1800 Solid State Hazardous
QTS-18161X-C000000 Carbon Monoxide
QTS-18221X-C000000 Ammonia 0-500 ppm
QTS-18261X-C000000 Freon R11 1000 ppm
QTS-18271X-C000000 Freon R12 1000 ppm
QTS-18281X-C000000 Freon R22 1000 ppm
QTS-18291X-C000000 Freon R123 100 ppm
QTS-18301X-C000000 Freon R134a 1000 ppm
QTS-18301X-C000000-R407c Freon R407c 1000 ppm
QTS-6000 Toxic w/o LCD Class 1 Div 1
QTS-61110X-E000000 Hydrogen Sulphide H2S 0-25 ppm Class 1 Div 1
QTS-61115X-E000000 Hydrogen Cyanide HCN 0-20 ppm Class 1 Div 1
QTS-61120X-E000000 Chlorine CL2 0-3 ppm Class 1 Div 1
QTS-61123X-E000000 Chlorine Dioxide CIO2 0-1 ppm Class 1 Div 1
QTS-61125X-E000000 Hydrogen Chloride HCL 0-10 ppm Class 1 Div 1
QTS-13001X-E000000 Oxygen O2 0-25% v/v Class 1 Div 1
QTS-61140X-E000000 Sulphur Dioxide SO2 0-6 ppm Class 1 Div 1
QTS-61150X-E000000 Nitrogen Dioxide NO2 0-6 ppm Class 1 Div 1
QTS-61160X-E000000 Carbon Monoxide CO 0-250 ppm Class 1 Div 1
QTS-61190X-E000000 Nitric Oxide NO 0-100 ppm Class 1 Div 1
QTS-61211X-E000000 Hydrogen H2 0-2000 ppm Class 1 Div 1
QTS-61220X-E000000 Ammonia NH3 0-50 ppm Class 1 Div 1
QTS-61240X-E000000 Ozone O3 0-3 ppm Class 1 Div 1
QTS-8000 Toxic w/LCD Class 1 Div 1
QTS-81110X-S000000 Hydrogen Sulphide H2S 0-25 ppm Class 1 Div 1 w/LCD
QTS-81115X-S000000 Hydrogen Cyanide HCN 0-20 ppm Class 1 Div 1 w/LCD
QTS-81120X-S000000 Chlorine CL2 0-3 ppm Class 1 Div 1 w/LCD
Model Number Configuration / Description
QTS-81123X-S000000 Chlorine Dioxide CIO2 0-1 ppm Class 1 Div 1 w/LCD
QTS-81125X-S000000 Hydrogen Chloride HCL 0-10 ppm Class 1 Div 1 w/LCD
QTS-81130X-S000000 Oxygen O2 0-25% v/v Class 1 Div 1 w/LCD
QTS-81140X-S000000 Sulphur Dioxide SO2 0-6 ppm Class 1 Div 1 w/LCD
QTS-81150X-S000000 Nitrogen Dioxide NO2 0-6 ppm Class 1 Div 1 w/LCD
QTS-81160X-S000000 Carbon Monoxide CO 0-250 ppm Class 1 Div 1 w/LCD
QTS-81190X-S000000 Nitric Oxide NO 0-100 ppm Class 1 Div 1 w/LCD
QTS-81211X-S000000 Hydrogen H2 0-2000 ppm Class 1 Div 1 w/LCD
QTS-81220X-S000000 Ammonia NH3 0-50 ppm Class 1 Div 1 w/LCD
QTS-81240X-S000000 Ozone O3 0-3 ppm Class 1 Div 1 w/LCD
Options
2 x SPDT relay PLUS RS-485 digital communications
QTS-8000 Combustible w/LCD Class 1 Div 1
QTS-81170X-S000000 Methane 0-100% LEL Class 1 Div 1 w/LCD
QTS-81171X-S000000 Acetylene 0-100% LEL Class 1 Div 1 w LCD
QTS-81172X-S000000 Ethane 0-100% LEL Class 1 Div 1 w LCD
QTS-81173X-S000000 Propane 0-100% LEL Class 1 Div 1 w LCD
QTS-81174X-S000000 Butane 0-100% LEL Class 1 Div 1 w LCD
QTS-81175X-S000000 Pentane 0-100% LEL Class 1 Div 1 w LCD
QTS-81176X-S000000 Octane 0-100% LEL Class 1 Div 1 w LCD
QTS-81177X-S000000 Hydrogen 0-100% LEL Class 1 Div 1 w LCD
QTS-81178X-S000000 Gasoline 0-100% LEL Class 1 Div 1 w LCD
Options
2 x SPDT relay PLUS RS-485 digital communications
Gas Detection Controllers
M-CONTROLLERx-00 Digital-Analog Controllers
Options
8 channel 4-20mA retransmission
M-RELAY-5X-2
M-RELAY-5X-4
M-RELAY-5X-6
M-RELAY-5X-8
Gas Detection Controllers
Q4C-R000 Multi-channel Controller Display and Alarm unit
with Relay board (4 x SPDT, 10 Amps)
6N1-ISO Six Analog Average, HI/LO, Difference & Binary Conversion
AAR Adjustable Analog to Relay Output
AFP Analog to Floating Point
AIM1 Analog Isolation Module 1:1 Output/Input
AIM2 Rescaling Analog Isolation Module
AIM3 Analog Isolation Module, 120 VAC Powered
ARM Analog Rescaling Module
ARM2 Analog Input to Dual 4-20mA Output
ASA Analog Signal Amplifier
ATL Four Adjustable Trip Point Relay Output
ATP Analog to PWM Output
AUD Floating Point to Analog Output
DMUX-4J PWM to 4 Relay Multiplexer (Jumpers)
DMUX-8J PWM to 8 Relay Multiplexer (Jumpers)
DRN3.1.0-135 Analog/PWM/Floating Pt. to “0-135 Ohm” Resistance
DRN3.1.0-270 Analog/PWM/Floating Pt. to “0-270 Ohm” Resistance
DRN3.1.0-500 Analog/PWM/Floating Pt. to “0-500 Ohm” Resistance
DRN3.1.0-1000 Analog/PWM/Floating Pt. to “0-1000 Ohm” Resistance
DRN3.1.0-1500 Analog/PWM/Floating Pt. to “0-1500 Ohm” Resistance
DRN3.1.0-2K Analog/PWM/Floating Pt. to “0-2K Ohm” Resistance
DRN3.1.0-3K Analog/PWM/Floating Pt. to “0-3K Ohm” Resistance
DRN3.1.0-4K Analog/PWM/Floating Pt. to “0-4K Ohm” Resistance
DRN3.1.0-5K Analog/PWM/Floating Pt. to “0-5K Ohm” Resistance
DRN3.1.0-10K Analog/PWM/Floating Pt. to “0-10K Ohm” Resistance
DRN3.1.0-20K Analog/PWM/Floating Pt. to “0-20K Ohm” Resistance
DRN3.1.0-40K Analog/PWM/Floating Pt. to “0-40K Ohm” Resistance
DRN4 Analog/PWM/Floating Pt. to 0-135 ohm (motor mount)
ENC1 Enclosure for Interface Device
EFP100 Floating Pt. to Pneumatic (100psi) w/Feedback, 41 scim bleed
EFP Floating Pt. to Pneumatic w/Feedback, 41 scim bleed
EFPG Floating Pt. to Pneu. w/Fdbk, 41 scim bleed, Gauge
EFP2 Flt. Pt. to Pneu. w/Fdbk, 750 scim Supply/Exhaust
EFP2G Flt. Pt. to Pneu. w/Fdbk, 750 scim S/E, Gauge
EFP2FS Flt. Pt. to Pneu. w/Fdbk, FailSafe, 750 scim S/E
EFP2GFS Flt. Pt. to Pneu. w/Fdbk, FailSafe, 750 scim S/E, Gauge
EPC Analog to Pneumatic w/Feedback, 41 scim Bleed
EPCG Analog to Pneumatic w/Fdbk, 41 scim bleed, Gauge
EPC2 Analog to Pneu. w/Feedback, 750 scim Supply/Exhaust
EPC2G Analog to Pneu. w/Feedback, 750 scim S/E, Gauge
EPC2LG Analog to Pneu. w/Fdbk, High Flow 1400 scim S/E, Gauge
EPC2GB Analog to Pneu. w/Bracket, Fdbk, 750 scim S/E, Gauge
EPC2FS Analog to Pneu. w/Feedback, FailSafe, 750 scim S/E
EPC2GFS Analog to Pneu. w/Fdbk, FailSafe, 750 scim S/E, Gauge
EPC2GFSB Analog to Pneu. w/Bracket, Fdbk, FailSafe, Gauge
EPW100 PWM to Pneumatic (100psi) w/Feedback, 41 scim Bleed
EPW PWM to Pneumatic w/Feedback, 41 scim Bleed
EPWG PWM to Pneumatic w/Fdbk, 41 scim bleed, Gauge
EPW2 PWM to Pneu. w/Feedback, 750 scim Supply/Exhaust
EPW2G PWM to Pneumatic w/Fdbk, 750 scim S/E, Gauge
EPW2FS PWM to Pneu. w/Feedback, FailSafe, 750 scim S/E
EPW2GFS PWM to Pneu. w/Fdbk, FailSafe, 750 scim S/E, Gauge
LPR Local Power Regulator (5-24 VDC Output)
MAO Manual Analog Override (2-I/O)
MDO2FS Manual Digital Override w/FailSafe (2-I/O)
MPOE Manual Pneumatic Override, Electric Switch Selectable
PHOTON4.1 RS485 Lighting Contactor Interface
PSG Programmable Signal Generator (Hand Held)
PTA PWM to Analog (Voltage or Current) Output
PTA2 PWM to Analog (0-10 VDC) Output
PTP100 Pneumatic (100psi) Sensor to Analog Output
PTP-3/15 Pneumatic (3-15psi) Sensor to Analog Output
PTP-3/30 Pneumatic (3-30psi) Sensor to Analog Output
PTS4.1 Floating Point (90-sec) to Pneumatic
PTS4.1G Floating Point (90-sec) to Pneumatic, Gauge
PXP100 Analog to Pneumatic (0-100psi) Output
PXP0.3 Analog to Pneumatic Output, No Bleed
PXP0.3G Analog to Pneumatic Output, No Bleed, Gauge
PXP1.3 Analog to Pneumatic, 73 scim bleed type
PXP1.3G Analog to Pneumatic, 73 scim bleed type, Gauge
PXP5.3 Analog to Pneumatic, 14 scim bleed type
PXP5.3G Analog to Pneumatic, 14 scim bleed type, Gauge
PXP7.3 Analog to Pneumatic, 41 scim bleed type
PXP7.3G Analog to Pneumatic, 41 scim bleed type, Gauge
PXP2.3 Analog to Pneumatic, 750 scim Supply/Exhaust
PXP2.3G Analog to Pneumatic, 750 scim S/E, Gauge
PXP2.3LG Analog to Pneumatic, High Flow 1400 scim, Gauge
PXP2.3FS Analog to Pneumatic, FailSafe, 750 scim S/E
PXP2.3GFS Analog to Pneumatic, FailSafe, 750 scim S/E, Gauge
RIM2 Two SPDT Relay Interface Module
RTI1 Resistance (100-500 ohm) to 4-20mA (Loop)
RTI2 Resistance (500-2200 ohm) to 4-20mA (Loop)
RTI3 Resistance (2200-5000 ohm) to 4-20mA (Loop)
SW1 Electric to Pneumatic Switch
TOB Dual Triac Output Booster
RT2602B Wireless Remote Sensor Input Concentrator
(Battery) – 2 DIs
RT2620A Wireless Remote Sensor Input Concentrator
(24VAC or Battery) – 4 DIs
RT2620AE Wireless Remote Sensor Input Concentrator
(24VAC or Battery) – 4 Dis & NEMA4
RT2620B Wireless Remote Sensor Input Concentrator
(battery Only) – 4 DIs
RT2620BE Wireless Remote Sensor Input Concentrator
(battery Only) – 4 Dis, NEMA4
RT2630A Wireless Remote Sensor Input Conc.
with 4 DI & 4 AI (20KOhm)
RT2630B or C Wireless Remote Sensor Input Conc.
with 4 DI & 4 AI (0-10VDC or 0-20mA)
RT2630AE or BE or CE Wireless Remote Input Conc.
with 4 DI & 4 AI NEMA4
BTM9000 Monitoring & Logging Software
BTM9010A Building Monitoring & Logging Software
MOD9200D-AC or DC TCP/IP, RTU, or ASCII Modbus Protocol Transceiver
MOD9000DE-AC or DC TCP/IP, RTU, or ASCII Modbus Protocol
Transceiver with NEMA 4
MOD9200BNT BACnet Transceiver
MOD9200BNT-E BACnet Transceiver with NEMA 4 enclosure
MOD9200LON- (A,B,C,D,E, or F) LonWorks Transceiver
MOD9200LON- (A,B,C,D,E, or F)-E LonWorks Transceiver NEMA4
RM9500-S2K WebLogger
RR2552B Spread Spectrum Router/Repeater
RR2552BE Spread Spectrum Router/Repeater (NEMA4)
RD2402D End device with 2 digital output wireless
module BACnet command
RD2402-24DC 24VDC power supply wireless output
module BACnet command
RD2402DE End device with 2 digital output, BACnet
command and NEMA4 Housing
RD2402DC-24DC 24VDC power supply wireless output module
BACnet command and NEMA4
RD2432D End device with 4 analog outputs, 4 digital output,
and BACnet command
RD2432D-24DC 4 Analog and 4 Digial outputs 24VDC
power supply wireless module
RD2432DE End device with 4 analog outputs, 4 digital output,
BACnet command and NEMA4 Housing
RD2432DE-24DC 4 Analog and 4 Digial outputs 24VDC power supply
wireless module and NEMA4
RD2432D End device with 4 DOs & 4 Aos
(works with network receivers)
RM2402D Receiver (coordinator) Module – 2 digital output
RM2432D Receiver Output Module – 4 DOs & 4 (0-10 or 0-5VDC) AOs
RM2432DE Receiver Output Module – 4 DOs & 4 Aos (NEMA4)
DH2630A Wireless Duct Humidity (3%) Sensor
DH2630B & C Wireless Duct Temp & Humidity (3%) Sensor
DT2630A Wireless Duct temp sensor (25-150)
DT2630B Wireless Duct temp sensor (-40 to 160)
DT2650A Wireless Average (4 points) Temp sensor
(0 to 150 F) – 20 ft element
ET2630A Wireless sensors in rugged case 0 to 160 F
FT2630A Wireless Immersion Temperature Sensor
Thermowell not included (25-125)
FT2630B Wireless Immersion Temperature Sensor
Thermowell not included (0-200)
FT5630 Wireless Hi Temp immersion sensor (up to -100 to 1100
with SS Well/NEMA4
OA2630 Wireless OSA Temp (-40 to 160 F) Sensor &
humidity with 8-plate solar shield
OST2630 Wireless Compact Outside Air (-40 to 160 F) NEMA4
SSH2630A Humidity Sensor (3%) with ruggedized enclosure
SSH2630B Temp & Humid (3%) Sensor with ruggedized enclosure
SST2630A, B & C Wireless Remote/Strap-on Temp. Sensors
SST2630AE, BE or CE Wireless Remote/Strap-on Temp. NEMA4 Housing
SST5630 Wireless Hi Temp Remote Temp Sensor
(-100 to 1100 F) in NEMA4 Encl
SST200A Strap-on Sensor (20KOhm) for RT2630A
WH2630A Wireless Wall Humidity (3%) Sensor
WH2630B Wireless Wall Temp & Humidity (3%) Sensors
WT2630A Wireless Wall Temp (32 to 104 deg F) Sensor
WT2630B Wireless Wall Temp Sensor with Setpoint & Push Button
WT2630C Wireless Wall Temp Sensor with Push button only
RC2100-2K Wireless Heating Controller (NEMA4)
RC2100YA-2K Heating Controller System with 4 Space
sensor & 1 OSA Sensor
RC2100YB-2K Heating Controller System with 8 Space
sensor & 1 OSA Sensor
RC2100YC-2K Heating Controller System with 12 Space
sensor & 1 OSA Sensor
CK2432D Programming Cable for RM2432D Receiver
CMT2620A Wireless Meter Input Module
CMT2620AE Wireless Meter Input Module NEMA4
EX2432D Output Extension Module for the RM2432
with additional 4AO & 4DO
RM9500-S2K WebLogger
Light Level
A/LLS Resistive Light Level Sensor 1/2″ NPT Clear Head
A/LLS-T Light Level Transmitter NEMA 4 Bell Box
LCD
A/LCD 4-20mA 4 to 20 mA Loop Powered
Power Supply
A/PS1.5 Adjustable Power Supply Snap Track Mount
Freeze Stats
A/FS-1 (1) SPDT, 20′, Manual Reset Freeze Stat
A/FS-1A (1) SPDT, 20′, Auto Reset Freeze Stat
A/FS-2 (2) SPDT, 20′, Manual Reset Freeze Stat
A/FS-2A (2) SPDT, 20′, Auto Reset Freeze Stat
A/FS-3 (1) SPDT, 10′, Manual Reset Freeze Stat
A/FS-3A (1) SPDT, 10′, Auto Reset Freeze Stat
A/FS-4 (2) SPDT, 10′, Manual Reset Freeze Stat
A/FS-4A (2) SPDT, 10′, Auto Reset Freeze Stat
A/FS-5 (1) SPDT, 6′, Manual Reset Freeze Stat
A/FS-5A (1) SPDT, 6′, Auto Reset Freeze Stat
A/FS-6 (2) SPDT, 6′, Manual Reset Freeze Stat
A/FS-6A (2) SPDT, 6′, Auto Reset Freeze Stat
A/DBZ-05 Capillary Mounting Brackets (Set of 6)
Thermowells
A/2.5″ 2.5″ Stainless Steel Two-Piece Thermowell
A/4″ 4″ Stainless Steel Two-Piece Thermowell
A/6″ 6.25″ Stainless Steel Two-Piece Thermowell
A/12″ 12″ Stainless Steel Two-Piece Thermowell
A/18″ 18″ Stainless Steel Two-Piece Thermowell
A/24″ 24″ Stainless Steel Two-Piece Thermowell
Machined Thermowells
A/M1″ 1″ Machined Stainless Steel Thermowell
A/M2.5″ 2.5″Machined Stainless Steel Thermowell
A/M4″ 4″ Machined Stainless Steel Thermowell
A/M6″ 6.25″ Machined Stainless Steel Thermowell
A/M12″ 12″ Machined Stainless Steel Thermowell
A/M18″ 18″ Machined Stainless Steel Thermowell
A/M24″ 24″ Machined Stainless Steel Thermowell
Monel Machined Thermowells
A/MON2.5″ 2.5″Machined Stainless Steel Thermowell
A/MON4″ 4″ Machined Stainless Steel Thermowell
A/MON6″ 6.25″ Machined Stainless Steel Thermowell
Thermal Grease
SG Silicon Thermal Grease, 8 oz
NSG Non-Silicon Thermal Grease, 2 oz
Shields & Covers
WS Weather Station
WSMP Weather Station Mounting Plate
LOCKING COVER Locking Cover for room enclosures
A/MOUNTING PLATE Oversized Plastic Wall Mounting Plate
A/MOUNTING PLATE White Oversized Plastic Wall Mounting Plate
MOUNTING PLATE 10 Commercial Grade Steel Wall Mounting Plate
Smoke Detectors SM Series (Ionization or Photoelectric)
SM501-N Duct Smoke Detectors (Ionization)
SM501-P Duct Smoke Detectors (Photoelectric)
WP-1 Weather Proof Enclosure for SM501
STS-1.0′ 1.0′ Sampling Tube for SM501
STS-2.5′ 2.5′ Sampling Tube for SM501
STS-5.0′ 5.0′ Sampling Tube for SM501
STS-10.0′ 10.0′ Sampling Tube for SM501
Smoke Detectors SL Series (Ionization or Photoelectric)
SL-2000-N Duct Smoke Detectors (Ionization)
SL-2000-P Duct Smoke Detectors (Photoelectric)
WP-2000 Weather Proof Enclosure for SL-2000
STN-1.0′ 1.0′ Sampling Tube for SL-2000
STN-2.5′ 2.5′ Sampling Tube for SL-2000
STN-5.0′ 5.0′ Sampling Tube for SL-2000
STN-10.0′ 10.0′ Sampling Tube for SL-2000
Multi-Application (No-Tools Required)
RT-3000-N Duct Smoke Detectors (Ionization)
RT-3000-P Duct Smoke Detectors (Photoelectric)
STN-1.0′ 1.0′ Sampling Tube for RT-3000
STN-2.5′ 2.5′ Sampling Tube for RT-3000
STN-5.0′ 5.0′ Sampling Tube for RT-3000
STN-10.0′ 10.0′ Sampling Tube for RT-3000
Smoke Detectors (Remote Accessories)
MS-RA Alarm LED, Single Gang
MS-RA/P Pilot LED, Alarm LED, Single Gang
MS-RA/R Alarm LED, Push Button, Single Gang
MS-RA/P/R Pilot LED,Alarm LED, Push Button, Single Gang
MS-RA/P/T Pilot LED, Trouble LED, Single Gang
MS-RA/FT/P Pilot LED, Trouble LED, Push Button, Single Gang
MS-KA/R Alarm LED, Key Reset
MS-KA/P/R Alarm LED, Alarm LED, Key Reset
MS-KA/P/R/T Alarm LED, Trouble LED, Key Reset
MS-RD Alarm LED, Single Gang
MS-F/T Trouble LED, Single Gang
MS-RH/P/A Pilot LED, Alarm LED, Horn, Single Gang
MS-RH/KA/P/R Pilot LED, Alarm LED, Key Reset, Horn, Double Gang
MS-RH/KA/P/A/T Pilot LED, Alarm LED, Trouble LED, Key Reset, Horn, Double Gang
MS-RH Horn, Single Gang
Control Transformers
LE-105 PV =24VAC, SV =24VAC, VA=40, 1 Hub, TC
LE-117 PV =120VAC, SV =24VAC, VA=50, 1 Hub, TC
LE-118 PV =120VAC, SV =24VAC, VA=75,
2 Hub, 3.75A Reset
LE-119 PV =120VAC, SV =24VAC, VA=75,
1 Hub, 3.75A Reset
LE-120 PV =120VAC, SV =24VAC, VA=96,
2 Hub, 4A Reset
LE-124 PV =120VAC, SV =24VAC, VA=150,
1 Hub, 10A Reset
LE-160 PV =120,240,277,480VAC, SV =24VAC, VA=50,
2 Hub, 2.25A Reset
LE-1175 PV =120VAC, SV =24VAC, VA=50, 2 Hub, TC
LE-1501 PV =120,208,240,480VAC, SV =24VAC, VA=75,
1 Hub, 3.75A Reset
LE-15013 PV =120,208,240,480VAC, SV =24VAC, VA=75,
2 Hub, 3.75A Reset
Relays
PAM-1 10.0 A form “C” contacts. Relay energized
by 24VDC/ 24VAC/120VAC
PAM-2 7.0 A form “C” contacts. Relay energized
by 24VDC/ 24VAC/120VAC
PAM-4 10.0 A form “C” contacts. Relay energized
from 9VDC to 40VDC
PAM-SD 7.0 A form “C” contacts. Relay energized
20VDC to 32VDC
RIC-1 7.0 A (1) SPDT dry form “C”. Relay energized
by 24VAC/24VDC/115VAC
RIC-2 7.0 A (1) DPDT dry form “C”. Relay energized
by 24VAC/24VDC/115VAC
RIC-3 Up to 10.0 A (1) SPDT dry form “C”. Relay
energized by 24VAC/24VDC (non-polarized).
DELAY UPON DE-ENERGIZATION: 2-3 Seconds
RIC-4 Up to 10.0 A (1) SPDT dry form “C”. Relay
energized by 24VAC/24VDC (polarized).
DELAY UPON DE-ENERGIZATION: 2-3 Seconds
Mounting hardware
UNIVERSAL CLIP Universal Mounting Clip (Sold in Bags of 20)
A/CAPILLARYCLIP Copper Capillary Clip (Each)
Command Relays with Status LED(Compatible with any ACI current switch
A/CR-DC-5A SPDT, 5A(NO)/2A(NC) @250VAC, 5A(NO)/3A(NC) @125VAC, 23-31.2 VDC Coils
A/CR-DC-12A SPDT, 12A@250VAC, 12A @ 30VDC, Status LED, 23-31.2 VDC Coils
A/CR-12DC-12A SPDT, 12A@250VAC, 12A @ 30VDC, Status LED, 10-15.6 VDC Coils
A/CR-24AC-10A SPDT, 10A@250VAC, 10A @ 30VDC, Status LED, 16-26.4 VAC Coil
A/CR-115AC-8A SPDT, 8A@250VAC, 8A @ 30VDC, Status LED, 80-132 VAC Coil
A/CR-230AC-8A SPDT, 8A@250VAC, 8A @ 30VDC, Status LED, 165-264 VAC Coil
. . . . . . 更多 A C I 楼宇自控系列产品,请来电来邮垂询: